Taquein Automation provides standards and customized solutions
for power controls that meets requirements
for both industrial and commercial environment.

Our range of solutions includes:

  • NEMA Enclosed Circuits Breaker’s type1, 3, 3R, 4, 4X, 12
  • NEMA7/4X 
  • IEC-Ex Hazardous Area Applications UL489/UL1066 & IEC Circuit Breakers IEC/UL60947 & UL508A Starters IEC/UL61800-5-1
  • Motor Drives & Starters UL/NEMA Geared Motors UL1008 Automatic Transfer Switch

SLD Preparation

A single-line diagram (SLD) is a high-level schematic diagram showing how incoming power is distributed to the equipment.

It is the blueprint for electrical systems. It is the first step in preparing an analytical response plan, allowing you to become thoroughly confidential with the electrical distribution system layout and design in your plant.

Protective Device Coordination

Protective device coordination is the very important part of design for electrical network as a part of Power system studies. Protective device coordination is also known as relay coordination and selective coordination for the power system studies.

Load Flow Analysis for Oil and Gas

Conducting load flow studies is an important requirement for the operations.

The load flow analysis is an important part of the power system study for any facility to run without problems.

We perform Load flow study for the assessment of the steady-state conditions of the electrical system, to determine the flow of power, current, voltage, real power, and reactive power in a system under any load conditions.

Arc Flash Risk Assessment

Taquein, has led huge ETAP studies & services for arc flash risk assessment partner for more than 3500 busbars & panels from LV to MV & HV.

Electrical arc flash is an electrical hazard present in the system which causes very dangerous electrical and fire accidents.

We help you address the NFPA & OSHA requirements of arc flash hazard analysis and mitigation by proper arc flash risk assessment of the system.

Short Circuit Analysis

Short circuit study is the process of analyzing an electrical system to determine the magnitude of fault currents that flows during the fault and comparing the obtained values with the ratings of installed equipment and short circuit protection devices. The short circuit analysis is an extensive engineering calculation done using software like ETAP for accurate results.

Harmonic Analysis

Harmonic analysis is the process of identifying the harmonic distortions that occur in the electrical distribution system.

Taquein provides turnkey solutions for Harmonic Analysis Services. Our power system harmonic analysis services are proven and economical suiting the client needs. We help customer to identify the source of harmonics and suppress them for a quality supply of power.